Overcurrent coordination software testing

Etap star tcc features are also demonstrated in it. However, other analytical techniques and high current testing have demonstrated that these two circuit breakers are selective to a much higher value, at least 39,600a. Introduction to protective device coordination analysis. Maintenance and testing of overcurrent protective devices. In this paper, the authors present an overcurrent protectionrelay testing. Software will contain features to model various protective devices, equipment damage curves and store the data for future use.

Test sets provide the customer the possibility to interact with industrial protocols. Product data for overcurrent protective devices specified in other division 26 sections and involved in overcurrent protective device coordination studies. Selective coordination enforcement in 600 v or less systems. Jan 21, 2014 a time current curve tcc plots the interrupting time of an overcurrent device based on a given current level. A circuit overload is an overcurrent that occurs when more current amperage is drawn from a circuit than the wiring of the circuit can safely handle. Dreiym engineering pllc can address your need for a protective device coordination study. The objective of a protection scheme is to keep the power system stable by isolating only the components that are under.

Protection coordination and antiislanding control of gridconnected pv systems. Overcurrent relay testing online seminar under construction. Eatons cymtcc software addresses time overcurrent protection for industrial, commercial and distribution power systems. Overcurrent protectionrelay testing with realtime digital simulator. Coordination time interval cti is the criteria to be considered for coordination. Oneday distribution overcurrent protection training. Medium voltage products technical guide protection criteria. For fuse systems, verification of selective coordination is quick and easy, merely adhere to fuse ampere rating ratios as indicated by the manufacturer. Etap star offers insight into troubleshooting false trips, relay misoperation, and miscoordination.

Such programs include short circuit analysis and device time current characteristics. The electrical system reliability, component and circuit protection, and overall safety are directly related to the reliability and performance of the overcurrent protective device and can depend upon whether the required testing and maintenance are performed as prescribed for the overcurrent protective device utilized. Facilities instructions, standards, and techniques volume 39. Fuses can only be used once and the maximum current that a fuse can interrupt is limited. Requires periodic maintenance and testing unlike static relays relay operation can be affected due to ageing of the components and dust, pollution resulting in spurious trips operation speed for an electromagnetic. Maintenance and testing of the overcurrent protective devices the electrical system reliability, component and circuit protection, and overall safety are directly related to the reliability and performance of the overcurrent protective device and can depend upon whether the required testing and maintenance are performed as prescribed for the overcurrent protective device utilized. Overcurrent protection in ac power systems technical. Os2t0801a calculate time delays using coordination studies.

Industry standard overcurrent protection schemes for mv transformers fed from switchgear circuit breakers include an instantaneous overcurrent relay device 50. Following selective coordination best practices design engineers must coordinate electrical systems so that the protective device closest to the fault opens first, and quickly enough, to prevent the upstream devices from tripping. Selective coordination is a design requirement newly added by both the 2005 and 2008 national electrical code to article 700 emergency systems see 700. Software will contain features to model various protective devices, equipment damage curves and.

Protection of power system by optimal coordination of. Protective device coordination protective device coordination study description. The overcurrent characteristic can be expressed as primary, secondary or relative values, and time. Pdf nonconventional overcurrent relays coordination. Selective coordination enforcement selective coordination. Maintenance and testing of overcurrent protective devices eep. Following selective coordination best practices consulting. Effective control of shortcircuit current, or fault current as it is commonly. Today, this involves the use of a software program that allows you to enter information such as types of equipment, conductor characteristics, spacing, and number of phases. If one looks at the definition of overcurrent in article 100, it indicates that this includes overloads, ground faults.

This is accomplished by isolating faulty components from the rest of the electrical network, keeping as much of the network stable and operational as possible. These curves are provided by the manufacturers of electrical overcurrent interrupting devices, such as fuses and circuit breakers. Feb 07, 2017 the simplest form of overcurrent protection is a fuse. These requirements will be discussed in a later section. Lack of coordination between overcurrent devices can result in upstream devices opening and needlessly interrupting power in other parts of the electrical distribution system. A time current curve tcc plots the interrupting time of an overcurrent device based on a given current level. Pesias joint chapter overcurrent protection for conductors cable sc capability 0. He is also the author of the relay testing handbook series and founder of valence electrical training services. Coordination, and other considerations copper bussmann. In this article, we will cover types of overcurrent, what overcurrent protection devices are, and their place in an electrical circuit. Sourceone performs shortcircuit and coordination studies to determine proper coordination of overcurrent protection devices.

Protective coordination requires modeling the entire electrical network. Pesias joint chapter overcurrent protection for transformers thermal damage mechanical damage ieee standards c57109tm1993 ieee guide for liquidimmersed transformer throughfaultcurrent duration ieee standards c3791tm ieee guide for protective relay applications to power transformers challenges. Home download center electrical software available fault current selective coordination spreadsheet. Medium voltage products technical guide protection criteria for medium voltage networks. Ge overcurrent device instantaneous selectivity tables. Chris is an electrical engineering technologist, a journeyman power system electrician, and a professional engineer. It is not a comprehensive coverage, but should help the ahj request the necessary documentation and facilitate checking. Distribution, substation, and plant engineers can benefit from using an overcurrent protection program in commercial, industrial, and utility applications to aid in clearing temporary faults and isolating permanent faults.

Overcurrent protection fundamentals r ced engineering. Overcurrent relay setting model for effective substation relay coordination international organization of scientific research 30 p a g e figure 3 alaoji short circuit analysis the fault current on 2kv and 33kv of alaoji substation where calculated using neplan software. Mar 15, 2016 following selective coordination best practices design engineers must coordinate electrical systems so that the protective device closest to the fault opens first, and quickly enough, to prevent the upstream devices from tripping. Distribution automation handbook prototype power system protection, 8. Control engineering understanding time current curves. Regardless of which method is used, a thorough understanding of timecurrent characteristic curves of overcurrent protective devices is essential to provide a selectively coordinated system.

Another common type of overload is a surge power draw. Design of protection coordination of a distribution. Pesias joint chapter 19 a b c f coordination for radial feeders. The standard level includes the manual test screen, semiautomatic and automatic tests for simple and advanced ramping, pickup and timing of over current. Pdf designing and testing protective overcurrent relay using. Any software testing company during its formation passes the step of the testing team formation. Enables coordination engineers to easily and efficiently. Low voltage breaker fuse coordination requires a minimum 0. Overcurrent coordination page 3 qualtech engineers, inc. Power system protection aims to protect electrical systems from faults that may occur. How to achieve selective coordination of circuit breakers. Oct 01, 2007 this type of fault is commonly used when testing electrical equipment for shortcircuit current ratings and overcurrent protective devices for interrupting ratings.

The electrical system reliability, component and circuit protection, and overall safety are directly related to the reliability and performance of the overcurrent protective device and can depend upon whether the required testing and maintenance are performed as prescribed. Its a predefined coordination time interval and it depends on the type of relays. This modeling effort requires the skills of someone experienced in modeling electrical circuits. On the contrary to other kinds of relays, fuses and reclosers, overcurrent.

Testing directional overcurrent relays that use phasetophase references. Powersystem protection is a branch of electrical power engineering that deals with the protection of electrical power systems from faults through the disconnection of faulted parts from the rest of the electrical network. Timecurrent curves cables the timecurrent curves for cables are also known. The definition of selective coordination indicated localization of all overcurrent conditions. Sourceone also conducts arc flash studies and provides arc flash training. For electromagnetic relays, cti is of the order of 0. Ge energy industrial solutions ge overcurrent device.

The groups primary tasks involve power system studies including short circuit, load flow, motor starting, overcurrent coordination, underground cable ampacity, ground mat, arcflash, harmonic load flow, transient stability. Protective device coordination is the process of selecting and arranging protective devices to limit the effects of an overcurrent shortcircuit situation to the smallest area. Overcurrent protection reyrolle 7sr10 overcurrent and. Coordination is the ability to move two or more body parts under control, smoothly and efficiently. Traditional timecurrent curve based coordination studies. Students attending this oneday tutorial will learn uptodate overcurrent protection line sectionalizing techniques. No one would dispute the importance of team cohesion, as it is the substructure for any enterprise, so lets talk about the coordination of the testing team. The software overlays the characteristics of each of the elements in both the it diagram and the directional. Selective coordination of overcurrent protective devices is required by the nec for a few building systems for a limited number of circuits that supply power to vital loads. Overcurrent is used for automatic testing of directional and nondirectional overcurrent relays with autoassessment of the trip time characteristic, the directional boundaries of the current stages, and the pickupdropoff ratio. You could give me directions like, if you head north for ten blocks and then east for three blocks, youll find the best bbq in the county. Software protocol test sets fanox self powered relays. Designing and testing protective overcurrent relay using real time digital simulation. If youve ever plugged in too many holiday lights in the same outlet and caused the breaker to trip, youve overloaded the circuit.

Coordination is typically measured using tests of handeye or footeye coordination such as throwing, catching or bouncing a. To determine the ratings and settings of fuses, breakers, relay, etc. The higher values available with many overcurrent devices will be shown on the tables in this reference publication, as well as some values determined by traditional curve overlay. The arc flash incident energy is calculated for the electrical system from the point of connection to the utility service, through the main service switchboards, downstream to switchboards, building distribution and branch circuit panelboards, and motor control centers under the guidance of nfpa70e and utilizing the ieee 1584 equations. Overcurrent relay coordination for phase and earth faults using etap proceedings of 7 th irf international conference, 27 april2014, pune, india, isbn. Selective coordination for critical systems per the 2014. However, the most important variable in the optimal coordination of overcurrent relays is the time multiplier setting tms. The goal of this project is to analyze the following circuit figure 1 and determine protective device coordination to achieve optimum equipment. Reliability of software software testing and checking. Facilities instructions, standards, and techniques volume 39 methods for coordinating system protective equipment internet version of this manual created september 2000 facilities engineering branch denver office denver, colorado the appearance of the internet version of this manual may differ from the original, but the contents do not. The main purpose of the protective coordination software is to produce oneline diagrams, calculation of relay settings and time current coordination drawings. Meaning of coordination in software testing qatestlab blog. Overcurrent relay setting model for effective substation. For a relay installed on a line, ps is defined by two parameters.

Overcurrent scenarios dictate the type of overcurrent protection that should be used. An important aspect to keep in mind is that protective devices in series, such as breakers two and three in figure 1, do not need to be coordinated because tripping of either breaker yields the same result, which is the. Overcurrent automatic testing of positivenegativezero. Etap star overcurrent device protection and coordination evaluation software provides an intuitive and logical approach to timecurrent characteristic curve selectivity analysis. So far, some researches have been carried out on coordination of overcurrent relays 37.

Selective coordination for critical systems per the 2014 nec. Overcurrent coordination setting guidelines transformers. Available fault current selective coordination spreadsheet. The objective of a protection scheme is to keep the power system stable by isolating only the components that are under fault, whilst leaving as much of the network as. Protection relay settings coordination study thermoplant. Coordination technique precise overcurrent relay usage asks for the knowledge of the short circuit current that can flow in each section of the power network. To test the protection and coordination settings of this system by generating tccs. Coordinating a system coordination quizzes coordination software references agenda. Protective device characteristics including fuses, sectionalizers and reclosers will be introduced followed by discussions concerning the coordination of these devices, using on demonstration and coordination software. Ieee continuing education seminar houston, tx november 34, 2015. Electrical department,kalol institute of technology and research institute, kalol, india 1aesha. Medium voltage products technical guide protection. This tutorial teaches the design of a protection coordination scheme for a power distribution network using etap. Nowadays coordination of overcurrent relays is a very important subject in different networks.

Overcurrent coordination guidelines for industrial power systems for industrial applications in the united states, overcurrent coordination is generally performed in accordance with the ieee recommended practice for protection and coordination of industrial and commercial power systems, standard 242 buff book with. Overcurrent coordination setting guidelines conductors. Os2t0405d instantaneous overcurrent testing using protection software. Protective device coordination study dreiym engineering. In this paper, the authors present an overcurrent protectionrelay testing procedure by a applying special simulation hardware for a realtime powersystem digital simulation rtds. Slide 5 protection objectives equipment protection. For circuits supplying power to all other loads, selective coordination is a. These curves are part of the product acceptance testing required by underwriters laboratories ul and. Coordination of overcurrent, directional and differential.

In the time it normally takes to check one coordination scheme manually, dozens of alternatives can be evaluated using a graphicsoriented program, because the. Manual operation of the circuit breaker is typically recommended to be completed. The radial distribution system is the cheapest to build and is widely used in sparsely populated. Groundfault current consists of any current which flows outside the normal circuit path. Creating tccs with software is a very simple procedure, but achieving the desired level of coordination can be difficult. Overcurrent protectionrelay testing with realtime digital. Overcurrent relay protection is given at b, c, d and e, that is, at the infeed position of. Thus fuses are only used in low voltage systems and. Optimal overcurrent relay coordination using optimized. Testing of molded case circuit breakers to assure proper overcurrent. The three major categories or types of overcurrent are overload, shortcircuit, and groundfault. Selective coordination is achieved when overcurrent. Use equipment designation tags that are consistent with electrical distribution system diagrams, overcurrent protective device submittals, input and output data, and recommended device settings.

1376 1549 648 1534 349 122 1418 938 150 294 1306 795 336 894 1414 928 1093 835 1185 1070 883 446 777 317 649 417 253 704 1505 1496 387 25 533 967 1100 567 434 1039 1267 869 220 1218 387 800 562 1322